Downloading the
software from the site:
Step 1:-Download
the insulation file form HP website:
Step 2:-
Copy the downloaded RPM file to the Linux server using WinScp.
Installing and
configuring the Hpacucli software:
Step 1:-If
there is an older version of ACU CLI installed on the system, please use below command to remove it first.
Redhat # rpm -e hpacucli*
Step 2:-
Go to the hapacucli.rpm path in the system and run the following command to
install the software.
Redhat:- rpm -ivhhapacucli.rpm
Step 3:-
Check for the hpacucli command with root user id.
--: Below are the
some useful commands :--
Utility Keyword abbreviations
|
|
Abbreviations
|
chassisname = ch
|
controller = ctrl
|
|
logicaldrive = ld
|
|
physicaldrive = pd
|
|
drivewritecache = dwc
|
|
hpacucli utility
|
|
hpacucli
|
# hpacucli
|
# hpacucli help
|
|
Note: you can use the hpacucli command in a script
|
|
Controller Commands
|
|
Display (detailed)
|
hpacucli> ctrl all show config
|
hpacucli> ctrl all show config detail
|
|
Status
|
hpacucli> ctrl all show status
|
Cache
|
hpacucli> ctrl slot=0 modify dwc=disable
|
hpacucli> ctrl slot=0 modify dwc=enable
|
|
Rescan
|
hpacucli> rescan
|
Note: detects newly added devices since the last rescan
|
|
Physical Drive Commands
|
|
Display (detailed)
|
hpacucli> ctrl slot=0 pd all show
|
hpacucli> ctrl slot=0 pd 2:3 show detail
|
|
Note: you can obtain the slot number by displaying the controller
configuration (see above)
|
|
Status
|
hpacucli> ctrl slot=0 pd all show status
|
hpacucli> ctrl slot=0 pd 2:3 show status
|
|
Erase
|
hpacucli> ctrl slot=0 pd 2:3 modify erase
|
Blink disk LED
|
hpacucli> ctrl slot=0 pd 2:3 modify led=on
|
hpacucli> ctrl slot=0 pd 2:3 modify led=off
|
|
Logical Drive Commands
|
|
Display (detailed)
|
hpacucli> ctrl slot=0 ld all show [detail]
|
hpacucli> ctrl slot=0 ld 4 show [detail]
|
|
Status
|
hpacucli> ctrl slot=0 ld all show status
|
hpacucli> ctrl slot=0 ld 4 show status
|
|
Blink disk LED
|
hpacucli> ctrl slot=0 ld 4 modify led=on
|
hpacucli> ctrl slot=0 ld 4 modify led=off
|
|
re-enabling failed drive
|
hpacucli> ctrl slot=0 ld 4 modify reenable forced
|
Create
|
# logical drive - one disk
|
hpacucli> ctrl slot=0 create type=ld drives=1:12 raid=0
|
|
# logical drive - mirrored
|
|
hpacucli> ctrl slot=0 create type=ld drives=1:13,1:14 size=300
raid=1
|
|
# logical drive - raid 5
|
|
hpacucli> ctrl slot=0 create type=ld
drives=1:13,1:14,1:15,1:16,1:17 raid=5
|
|
Note:
|
|
drives - specific drives, all drives or unassigned drives
|
|
size - size of the logical drive in MB
|
|
raid - type of raid 0, 1 , 1+0 and 5
|
|
Remove
|
hpacucli> ctrl slot=0 ld 4 delete
|
Expanding
|
hpacucli> ctrl slot=0 ld 4 add drives=2:3
|
Extending
|
hpacucli> ctrl slot=0 ld 4 modify size=500 forced
|
Spare
|
hpacucli> ctrl slot=0 array all add spares=1:5,1:7
|
Regards,
MMM.
No comments: